  • Gasman Single Gas Detector

Gasman Single Gas Detector

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
77 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Gasman Single Gas Detector

 

Overview

 

Gasman is a range of rugged, compact single gas personal monitors designed for use in the toughest environments. Its stunningly compact and lightweight design makes it ideal for use in industries such as oil and gas, chemical plants (with exotic gases), steel works (special CO sensor), hospitality (CO2) and waste and water works.

Weighing just 130g, it is extremely durable, with high impact resistance and dust/water ingress protection, loud 95 dB alarms, a vivid red/ blue visual warning, single-button control and an easy-to-read, backlit LCD display to ensure clear viewing of gas level readings, alarm conditions and battery life. Data and event logging are available as standard, and there is a built-in 30 day advance warning when calibration is due.

Gasman is also available in a safe area CO2 version offering 0-5% carbon dioxide measurement.

Specifications

Size 90 x 48 x 24 mm (3.5 x 1.9 x 0.95 ins) Weight Flammable: 138g (4.9oz)
Toxic: 118g (4.1oz)
Oxygen: 129g (4.6oz)
Carbon monoxide: 139g (4.9oz) Typical response times (T90) Flammable:  20s
Toxic gas:  20s
Oxygen:  10s  Alarms Audible: 95dB; Multiple alarm options let you select distinctive tones for different alarm levels
Visible: Dual colours red/ blue flashing LEDs in a gas hazard
Internal vibrating alarm Display Custom LCD with backlight, with display of gas concentration. Graphic symbols for battery (with proportional indication of remaining operation time), and display mode. Start up indication when calibration is due within 30 days, calibration overdue or service required.
Normal display: Real time gas concentration levels
Display recall: Peak readings and TWA Data logging Full timed datalogging with adjustable sample rate, set to 1 min. data rate as default.
900 hours storage at 1 min. interval (54,000 logs), >4800 events Battery Rechargeable lithium battery for all gas types
Non-rechargeable lithium battery for toxics and oxygen (excluding CO2) Operating time* Rechargeable: 12 hours minimum for flammable unit
Non-rechargeable: Up to 2 years  Sampling  Optional manual aspirator Operating temperature** -20°C to +65°C (-4°F to +149°F) Humidity 20 to 90% RH Ingress protection IP65 Approvals Europe: Toxic or O2: ATEX II 1G Ex ia IIC T4 Ga (-20°C ≤ Ta ≤ +65°C) BASEEFA04ATEX0384
Flammable: ATEX II 2G Ex ia d IIC T4 Gb (-20°C ≤ Ta ≤ +65°C) BASEEFA04ATEX0383
International: Toxic or O2: IECEx BAS05.0039
                        Flammable: IECEx BAS05.0038
North America: CSA Class 1 Groups A,B,C,D Division 1 Standards Europe: EN60079-0, EN60079-11, EN60079-1
North America: CSA22.2, 152EN50270, EN50271, IEC61508, EN61779, EN45544 PC Interface RS232 connection from interface module in charger
RS232/USB converter available Calibration Gasman can be routinely calibrated using Portables PC software or by using Checkbox IMH

*Operating time will depend on operating pattern and alarm occurrence. Frequent or long lasting alarms and use of the optional confidence beep will reduce battery life.

**Toxic and oxygen sensors are not rated for continuous operation at high temperatures. Consult Crowcon if operating temperatures are likely to exceed 40°C (104°F) for extended periods.

Gases and Ranges

Required ranges and alarms vary by country and application and these can be configured as required. Each gas channel can have two instantaneous alarm levels set. Toxic units also have Time Weighted Average (TWA) alarms.

Flammable gas calibration is available for methane, propane, butane, pentane, hydrogen and
ethylene as standard.

Gasman is also available in a safe area CO2 version offering 0-5% carbon dioxide measurement.

Gas Range Standard Alarm (UK) Ammonia (NH3)  0-100 ppm  25 ppm Carbon monoxide (CO)  0-500 ppm  30 ppm Carbon dioxide (CO2)  0-5% vol.  0.5% vol. Chlorine (Cl2)  0-20 ppm  0.5 ppm Flammable  0 - 100% LEL  20% LEL Fluorine (F2) 0-1 ppm    0.1 ppm Hydrogen (H2)  0-2000 ppm  N/A Hydrogen cyanide (HCN)  0-25 ppm  5 ppm Hydrogen fluoride (HF) 0-10 ppm  1 ppm Hydrogen sulphide (H2S) 0-100 ppm  5 ppm Nitric oxide (NO) 0-100 ppm  25 ppm Nitrogen dioxide (NO2)  0-20 ppm  1 ppm Oxygen (O2)  0-25% vol.  19% / 23% vol. Ozone (O3)  0-1 ppm  0.1 ppm Phosphine (PH3)  0-5 ppm  0.2 ppm Phosgene (COCL2)  0-1 ppm  0.1 ppm Sulphur dioxide (SO2)  0-20 ppm  1 ppm

 