Triple Plus+ is the latest generation of the respected "Triple" family of toxic, oxygen and flammable gas detectors. With over 90,000 units sold to oil and gas, chemical, utility and manufacturing companies worldwide, their combination of ruggedness, reliability, ease of use and sensor flexibility has set the standard for multigas portables.
IR option
IR sensors have very high resistance to interference or inhibition by other gases and are suitable for both high gas concentrations and use in inert (oxygen free) backgrounds where catalytic pellistor sensors would perform poorly.
The unique design of the Crowcon IR sensor module used in Triple Plus+ IR allows measurement of hydrocarbons at both %LEL and % volume ranges making this instrument ideal for tank and line purging applications.
- No poisoning effects - works well where catalytic pellistors would perform poorly
- Long life sensor and no burnout - reduced cost of ownership
- % vol. measurement for purging applications - offers flexibility
- % LEL measurement in air or inert backgrounds
- Single or dual range measurement
- IR CO2 detection, 0-5%
Specifications
Size
118 x 200 x 73mm (4.65 x 7.8 x 2.9ins)
Weight
880g gas (31oz)
Alarms
Piercing, rapid intermittent, piezo-electric tone 85 dB at 1 m Confidence blip (selectable) Distinctive double blip for low battery with user accept
Gas hazard: vivid flashing red LED Instrument is working: slow flashing green LED Low battery: distinctive double flash of green LED
Display
2 lines of 24 characters, dot matrix high contrast LCD with back light operating for 30 minutes Values and units for up to 4 gases displayed simultaneously at current, TWA or peak levels Low battery, pump failure, real time and elapsed time, calibration and configuration data also displayed
Data logging
Adjustable sample rate, 100 hours at 1 minute sample rate (maximum 6000 data points per channel), logging of events, user and site
Battery
Rechargeable Li-ion batterypack
Standard instrument >12 hours
Pumped instrument >10 hours
Charging: Dual rate drop-in charger; Dual rate charger/PC interface
Expected sensor life
Flammable: 5 years (Triple Plus+)
IR: 5 years (Triple Plus+ IR)
Toxic: 3 years
Oxygen: 2 years
Typical response times
Methane 20s (Triple Plus+) IR 20s (Triple Plus+IR), Oxygen 10s, typical Toxic Gas 20s
Sampling
Optional internal electric pump with on/off button
Operating temperature
-20°C to +50°C (-4°F to 122°F)
Humidity
20 to 90% RH non-condensing
Ingress protection
IP65
Approvals
Europe: ATEX II 2G: Ex ib d IIC T4 Gb
North America: Class I Division 1, Groups A, B, C and D
Safety standards
Europe: EN50014, EN50020, EN50081-2, EN50270, EN50082-2
North America: UL 913, CSA 22.2 No.157 (SFA3009 Triple Plus+)
Calibration
Tetra can be routinely calibrated manually using the menu, using Crowcon Protables PC software or automatically using Checkbox IMH.
Accessories
Standard: Manual, shoulder strap and allen keys (pumped units include additional flow plate, 2m hose and pouch)
Optional: Leather carry case, straight and telescopic probes, water trap, baffle plate, aspirator, calibration flow adaptor and hose