Designed for group protection, area monitoring and providing a virtual fenceline, Detective+ is a rugged, interconnectable, multigas temporary area monitor. Building on Crowcon's experience in pioneering this category of detector, Detective+ has earned a reputation for reliability and versatility in demanding environments stretching from offshore platforms to the sands of the Middle East.
New! Detective+ is now wireless.
Detective Wireless is a wireless module that gives you up to 100 meters range excluding the use of cables.
The Detective Wireless modules can also be used as a repeater giving you a stronger signal in those areas that are built up and that have issues with signal strength.
Detective Wireless is backwards compatible enabling use with all version of Detective and Detective+, so it can be used on your existing fleet
Specifications
Size
640 x 455 x 455mm (25.2 x 17.9 x 17.9ins)
Weight
7.5kg (19lbs)
Alarms
Three large, top mounted red LED clusters and a single red LED on control panel.
Alarm mode: LED clusters flash in quick succession. LED clusters of linked Detectives repeating the alarm, flash
slower than LED lights on those Detectives sensing the hazard
Normal working: Slow flashing green LED
Battery low: Rapid flashing green LED
Wailing alarm, omni-direction siren, 104 dBA at 1m
Display
High contrast LCD with back light. Values and units for up to 4 gases displayed simultaneously at current, TWA or peak levels, low battery, real time and elapsed time calibration and configuration data also displayed.
Battery
125hrs at 10-second intervals (45,000 logs)
Event logging
Alarm, over range, calibration, bump, on/off, TWA, 1000 events
Battery
Standard 6V, 7.2Ah, sealed lead acid battery pack
Optional 6V, 12Ah high capacity pack
Up to 36 hours with flammable/ CO2 sensor fitted with 7.2Ah battery
Up to 60 hours with optional 12Ah battery pack
Typical response times
Methane 20s, oxygen 10s, typical toxic gas 20s, IR 20s
Operating temperature
-20
°C to +50
°C (-4
°F to 122
°F)
Expected sensor life
Flammable 5 years, toxic 3 years, oxygen 2 years minimum, IR>5 years
Humidity
0-95% RH non-condensing
EMC
EN 50270, FCC CFR47 Part 15
Ingress protection
IP65
Approvals
Europe: ATEX II 2G EEx ib d IIC T4
International: IECEx EEx ib d IIC T4
Standards
EN50014, EN50018, EN50020, EN50104, EN45544, IEC60079-0/-1 IEC60079-11
PC Interface
Via RS232 lead. Portables PC software can be used to set alarms, clock, datalogging interval and password, manages datalogging giving graphical display of instrument log file and allows to export to spreadsheet.
Calibration
Quick calibration using internal menu command, Portables PC or the Crowcon CheckBox IMH management system
Accessories
Baffle plate, interconnecting leads, RS232 communications lead
Sampling
Internal electric sampling pump option, manual aspiration
Linked Detectives
Up to 12 units can be linked to provide perimeter or area monitoring
Gases and Ranges
Required ranges and alarms may vary by country and application and these can be configured as required.
Gas
Range
Typical Alarms
Flammable gas
0-100 LEL
20% LEL
Oxygen (O2)
0-25%
19% & 23%
Hydrogen sulphide (H2S)
0-50 ppm
10 ppm
Carbon monoxide (CO)
0-500 ppm
35 ppm
Sulphur dioxide (SO2)
0-10 ppm
2 ppm
Chlorine (Cl2)
0-5 ppm
0.5 ppm
Nitrogen dioxide (NO2)
0-10 ppm
2 ppm
Phosphine (PH3)
0-5 ppm
0.5 ppm
Ammonia (HN3)
0-50 ppm
25 ppm
Ammonia (NH3)
0-1000 ppm
n/a
Hydrogen (non-flammable levels)
0-2000 ppm
n/a
Hydrogen cyanide (HCN)
0-25ppm
10ppm
Hydrogen chloride (HCl)*/+
0-10 ppm
5ppm
Chlorine dioxide (ClO2)+
0-1 ppm
0.1 ppm
Hydrogen fluoride (HF)+
0-10 ppm
1 ppm
Ethylene oxide (C2H4O)*
0-10 ppm
5 ppm
Volatile organic*/+
1-100 ppm
n/a