Offering detection of up to 5 gases in a compact and rugged solution, Gas-Pro has an easy-to-read top mount display combining ease of use and user focused features.
An optional internal pump, activated with the flow plate, takes the pain out of pre-entry testing and allows Gas-Pro to be worn either in pumped or diffusion modes
NEW! IR Sensor Technology
Gas-Pro IR detects potentially explosive gases in conditions where a pellistor-based catalytic sensor may struggle, especially in a low oxygen environment. The infrared measurement gives improved reliability and measures gas in two different wavelengths: one that absorbs gas and the other does not. With little chance of being poisoned, the Gas-Pro IR is inherently safer and saves the need of regular and expensive pellistor replacement when used in likely contaminated environments
Specifications
Size
43 x 130 x 84mm (1.7 x 5.1 x 3.3ins)
Weight
309g 4 gas (10.8oz)/ 340g pumped (11.9oz)333g 5 gas (11.7oz)/ 362g pumped (12.7oz)
Alarms
Audible >95dB @ 30cm (98dB @30cm in loud mode)
Visual - all angle dual red/blue LEDs
Vibrating alert
Display
Top mount for ease of view with dual colour backlight (green/red)
Data logging
125hr at 10-second intervals (45,000 logs)
Event logging
Alarm, over range, calibration, bump, on/off, TWA, 1000 events
Battery
Rechargeable Li-ion, >14hr (13 hours pumped operation) based on CH
4, O
2, H
2S, CO
Typical charge time 7.5hr
Sampling
Internal pump as option
Operating temperature
-20°C to +55°C (-4°F to +131°F)
Storage
-25°C to +65°C (-13°F to +149°F)
Humidity
10 to 95% RH+
Ingress protection
Independently tested to IP65 and IP67
Approvals
IECEx: Ex d ia IIC T4 Gb Tamb -20°C to +55°C
ATEX: II 2 G Ex d ia IIC T4 Gb Tamb -20°C to +55°C
UL: Gas detector use in hazardous locations Class 1, Division 1, Groups A, B, C, and D only as to intrinsic safety
INMETRO
Compliance
FCC and CE. Complies with EMC Directive 2014/30/EU, EN50270 and ICES-003
Interface
Data connection for gas test solutions and direct to PC
Charging
Direct connection to multi-regional power supply
Vehicle charger adaptorDesktop cradle
USB power and communications lead
Gases and Ranges
Gas
Range
Typical Alarms
Resolution
Ammonia (NH
3)
0-100ppm
25ppm
1ppm
Carbon dioxide (CO
2)
0-5% vol.
0-5% vol.
0.01% vol.
Carbon monoxide (CO)
0-2000ppm
30ppm
1ppm
Carbon monoxide (CO)
0-500ppm
30ppm
1ppm
Carbon monoxide
(hydrogen filtered)
0-2000ppm
30ppm
1ppm
Chlorine (Cl
2)
0 - 5ppm
0.5ppm
0.1ppm
Dual toxic (CO-H
2S)
H
2S 0-100ppm
CO 0-500ppm
5ppm
30ppm
1ppm
1ppm
Flammable
0-100% LEL
20% LEL
1% LEL
Hydrogen sulphide (H
2S)
0-100ppm
5ppm
1ppm
Nitrogen dioxide (NO
2)
0-20ppm
1ppm
0.5ppm
Oxygen (O
2)
0-25% vol.
19% / 23% vol.
0.1% vol.
Ozone (O
3)
0-1ppm
0.1ppm
0.01ppm
Sulphur dioxide (SO
2)
0-20ppm
1ppm
0.1ppm
Chlorine dioxide (ClO
2)
0-1ppm
0.1ppm
0.1ppm
Nitric oxide (NO)
0-100ppm
25ppm
1ppm